Free Consult · $500 Off · Most Installs Done in 1 Day

What Is The Egress Code In NY?

5.0from 69+ Google reviews
What Is The Egress Code In NY | Egress of Long Island

Last updated: September 2026

New York’s egress rule is Section R319 of the 2025 Residential Code of New York State, effective December 31, 2025, subject to the state’s transition period. Basements and sleeping rooms generally need an emergency escape and rescue opening with a net clear opening of at least 5.7 square feet (5 for grade-floor openings, where the bottom of the opening is no more than 44 inches above or below the ground outside), 24 inches high, 20 inches wide, and its bottom edge no higher than 44 inches above the floor.

Understanding New York’s Egress Window Code Requirements

If you’re planning to finish a basement, add a bedroom, or update your home’s emergency exits in New York State, understanding egress window code requirements is essential. These regulations aren’t just bureaucratic red tape. They’re designed to save lives by ensuring everyone has a safe way out during emergencies.

What is an Egress Window?

An egress window is a window specifically designed and installed to provide a safe emergency exit from a bedroom or basement. According to the International Code Council, egress windows must meet strict size and accessibility requirements to ensure that occupants can escape and emergency responders can enter if needed.

New York State Egress Window Requirements

New York follows the 2025 Residential Code of New York State (RCNYS), which is based on the 2024 International Residential Code and took effect December 31, 2025. Here are the key requirements you need to know:

Minimum Size Requirements

RequirementAll other openingsGrade-floor openings
Net Clear Opening Area5.7 sq. ft.5.0 sq. ft.
Minimum Opening Height24 inches24 inches
Minimum Opening Width20 inches20 inches
Maximum Sill Height44 inches from floor44 inches from floor

It’s important to note that the minimum width and height requirements alone don’t guarantee the minimum area requirement. Your window dimensions must be large enough to provide the total required open area when the window is fully opened.

Window Operation Requirements

The New York Department of State specifies that egress windows must be:

  • Operable from the inside without special knowledge, keys, or tools
  • Maintained in working condition at all times

These operation requirements ensure that anyone can quickly open the window during an emergency, even in stressful situations or with limited visibility.

Window Well Requirements for Below-Grade Windows

If your egress window is below ground level (like in a basement), you’ll need a properly sized window well:

  • Minimum Area: 9 square feet
  • Minimum Dimensions: 36 inches in both width and projection (distance from the wall)
  • Ladder Requirements: If the well is deeper than 44 inches, you must install a permanent ladder or steps that:
    • Encroach no more than 6 inches into the required well size, and ladders project at least 3 inches from the wall
    • Are at least 12 inches wide
    • Have rungs spaced no more than 18 inches apart

Proper drainage for window wells is also critical to prevent water accumulation. At Egress of Long Island, our professional egress window installation includes a drainage stone base and a 50-gallon NDS Flo-Well storm water leaching system that isn’t tied into your footing drains or sump. For more on why wells fill with water, see our guide to egress window well drainage.

Location Requirements

According to New York code:

  • Every bedroom must have at least one egress window or exterior door
  • A basement with habitable space needs at least one emergency escape opening, and each basement bedroom needs its own

These requirements apply to both new construction and renovations of existing spaces. Wondering whether a basement room can be used for sleeping? Our answer explains what the code says.

Additional New York-Specific Considerations

Local Variations

While the state code establishes minimum requirements, local jurisdictions may have additional or stricter regulations. For example:

  • New York City follows its own building code with some variations
  • Historic districts may have special requirements regarding window appearance
  • Nassau and Suffolk Counties on Long Island sometimes have specific requirements due to high water tables

Always check with your local building department before beginning any egress window project.

Bars, Grilles, and Covers

If security is a concern, the code does permit protective devices over egress windows, but they must:

  • Be releasable or removable from the inside
  • Not require keys, tools, or special knowledge to operate
  • Not reduce the minimum required dimensions of the egress opening

Why Proper Egress Windows Are Critical

Egress windows give you a way out in an emergency. They provide:

  1. Emergency Escape: A way out when stairs or doors are blocked
  2. Rescue Access: A way for firefighters to enter and reach you
  3. Natural Light: Improved livability and code compliance for basements
  4. Legal Compliance: Meeting requirements for legal bedroom designation
  5. Home Value: A legal basement bedroom can add appeal and usable room, though appraisers usually report below-grade space separately

Common Code Compliance Issues in New York

These are common egress compliance issues in Long Island homes:

1. Undersized Windows

Many older homes have basement windows that are too small to meet current egress requirements. These typical “hopper” style basement windows might be:

  • Too narrow (less than 20 inches wide)
  • Too short (less than 24 inches high)
  • Too small in total area (less than 5.7 square feet, or less than 5 square feet for grade-floor openings)

2. Improper Sill Height

Windows with sills positioned higher than 44 inches from the floor fail to meet egress code. This height limit ensures that people of all ages and abilities can access the window in an emergency.

3. Inadequate Window Wells

Many existing window wells are:

  • Too small in area
  • Too narrow
  • Lacking required ladders
  • Without proper drainage

4. Non-Compliant Security Features

Security bars or window guards that can’t be easily opened from inside create dangerous situations during emergencies.

Consequences of Non-Compliance

Failing to meet egress window requirements in New York can lead to:

  • Failed home inspections
  • Inability to legally sell rooms as bedrooms
  • Liability issues if injuries occur
  • Fines from local building departments

More importantly, non-compliant windows put your family at risk during emergencies.

Professional Installation Ensures Compliance

At Egress of Long Island, we specialize in bringing homes up to code with professional egress window installation. Our services include:

  • Code-compliant window selection
  • Professional foundation cutting
  • Properly sized window well installation
  • Drainage system installation
  • Compacted backfill, restoration of the disturbed area, and broom-finished cleanup, with interior finish available as an extra
  • Clear guidance on what your town requires for permits (the homeowner arranges permits and any engineered drawings)

Our team completes most installations in just one day, minimizing disruption to your home life.

Window Well Systems and Covers

For basement egress windows, a properly designed window well is essential. Our window well systems include:

  • Code-compliant dimensions
  • Effective drainage systems
  • Durable construction
  • A steel safety grate with a clear polycarbonate cover, included

Window well covers can enhance safety and prevent debris, animals, and weather from affecting your egress window, while still meeting emergency exit requirements. To compare the wells themselves, see our guide to egress window well options on Long Island. If your current well is cracked, rusted or bowing, read about window well replacement.

Conclusion

Understanding and following New York State’s egress window code requirements is essential for safety, legal compliance, and home value. While the regulations might seem complex, they’re designed with a simple goal: ensuring everyone can escape quickly in an emergency.

If you’re considering a basement renovation, bedroom addition, or just want to bring your home up to current safety standards, contact our highly-rated egress window services for a professional assessment. We’ll ensure your egress windows meet all New York code requirements while enhancing your home’s safety and value.

Frequently Asked Questions About the NY Egress Code

Is the egress window code section R310 or R319 in New York?

In the 2025 Residential Code of New York State, emergency escape and rescue openings are covered by Section R319. Section R310 now covers smoke alarms. Some older articles and town plan sheets still cite R310 for egress, so check which code edition your building department is applying to your project.

Are there exceptions to the basement egress window rule in New York?

Yes, a few. Section R319.1 exempts basements used only for mechanical equipment up to 200 square feet and storm shelters built to ICC 500. In a home with an automatic sprinkler system, basement sleeping rooms can skip their own opening if the basement has one compliant means of egress plus one escape and rescue opening, or two compliant means of egress. For existing basements, Appendix BO also applies, and it requires an opening that meets R319 when an existing basement is reconfigured to create habitable space or a new sleeping room (BO105.11). Confirm with your building department.

How big does an egress window well have to be in New York?

An area well must be at least 9 square feet, with at least 36 inches of horizontal projection and width, and large enough for the window to open fully. A well deeper than 44 inches needs a permanently affixed ladder or steps. A ladder may encroach up to 6 inches into the required well size.

Can you put bars or a cover over an egress window well?

Yes, but they cannot shrink the required opening, and they must release or remove from the inside without a key, a tool, or more force than the window itself takes to open. Section R319.4.4 applies to bars, grilles, covers and screens placed over the opening, a bulkhead enclosure or the area well.

Can you replace an old basement window with a smaller one?

Sometimes. Section R319.5 exempts the replacement of an existing emergency escape and rescue opening from the size rules and the bars and covers rule only if the new window is the manufacturer’s largest standard size that fits the existing frame or rough opening, has the same operating style or one with an equal or greater opening area, and is not part of a change of occupancy. A smaller replacement than that, or a new opening, has to meet the full size rules. Appendix BO also applies to existing basements, so confirm with your building department.

Source: NYS Department of State, 2025 Residential Code of New York State (publication July 2025), Section R319 and Appendix BO.

Related Resources


Note: Building codes may change over time. We recommend confirming current requirements with your local building department before beginning any egress window project.

We install in Nassau County and Suffolk County, all the way out to Montauk. Permit offices and fees differ by town, so find your area.

Thinking about an egress window, well or walkout?

Book a free consultation and get $500 off. We'll look at your basement, your yard and what your town requires, then give you a straight quote. Most installs are done in 1 day.

More to Explore
Egress window installation in progress on Long Island, with an installer setting paver caps on a block well

Best Time of Year to Install an Egress Window on Long Island

Egress window well protected by a metal frame and mesh grate cover on Long Island, NY

How to Winterize a Window Well Before Long Island’s First Freeze

Inside a block-built masonry egress window well showing the ladder, drainage stone and floor drain on Long Island, NY

Egress Window Well Drainage on Long Island: Why Wells Fill With Water and What to Do About It

We install across Nassau County and Suffolk County, all the way out to Montauk. See all service areas.